Specifications

This appendix lists the specifications for the SuperStack II Hub 100.


Hub Specifications

Physical Dimensions

Width:

43.94 cm (17.3 in.)

Height:

4.37 cm (1.72 in.)

Depth:

30.48 cm (12 in.)

Weight:

5.5 kg (12 lb)

Environmental Operating Ranges

Operating temperature:
Hub 100 TX:
Hub 100 T4:


0° to 50 °C (32° to 122 °F)
0° to 50 °C (32° to 122 °F)

Storage temperature:

-30° to 60 °C (-22° to 140 °F)

Humidity:

10% to 90% relative humidity, noncondensing

Altitude:

3,050 m (10,000 ft) operating

Power Requirements

AC input voltage:

100-240 VAC, 47-63 Hz

Inrush current:

20 A peak for 1/2 cycle @ 250 VAC

AC input isolation:

2000 VAC

Power consumption:

40 W maximum

Heat output:

136.5 BTU/hr

Fuse:

Fast-blow 2 A, 250 V

Repeater Classification

SuperStack II Hub 100 TX

Class II or Class I

SuperStack II Hub 100 T4

Class I

[previous] Clear Spacer [next]