Controller Display Option
When the controller system screen is first selected, the screen in Figure 3-12 is displayed. The fields in this screen are:
Description Shows the product name of the Management Controller Module.
Boot Release Shows the boot release number of the Management Controller Module.
Model Number Shows the 3Com model number for the selected module.
Serial No. Shows the serial number of the Management Controller Module. This number is important and should be noted in case the Management Controller Module ever needs to be returned for servicing.
Main Release The main release number of the Management Controller Module software.
Checksums Used by the Management Controller Module for internal error handling. These values may be useful to your technical support representative in the event of problems.
Uptime Shows the time in hours, minutes and seconds that the unit has been powered on and operating.
Battery Displays the status of the internal backup battery. The AccessBuilder 7000 supports a real time clock, during power off the AccessBuilder 7000 retains the time and date using the backup battery.
Reference Provides a text field for you to enter the name of the unit so that it can be identified. We suggest that you use something that indicates the unit's geographical position. For example: AB7000-HQ1.
Contact Provides a text field for you to enter the name or telephone number of the person responsible for the AccessBuilder 7000 who can be contacted in the event of problems.
Controller Location Provides a text field for you to enter location of the Management Controller Module/AccessBuilder 7000. This field is useful if the unit is managed remotely and is installed in a large equipment room. You can enter the rack number and position so that engineers can quickly locate the unit in the event of a problem.
Time Displays the system time. Type the new time if you want to change the system clock time.
Date Displays the system date. Type the new date if you want to change the system date.
The list at the foot of the screen shows the last five Management Controller Module alerts, what the alert was, and when the alert encountered.

Setting SNMP Parameters
Press [CTRL]+[N] from the Controller screen to display the option screen shown in Figure 3-13.
You only need to complete this screen if you intend to use an SNMP manager to configure the AccessBuilder 7000 and its modules.

Figure 3-13 SNMP Parameters Screen

This screen allows you to set the SNMP community strings and configure remote SNMP managers authorized to manage the unit.
Community strings act as a sort of password in SNMP. If the SNMP management software does not send the right community string to the AccessBuilder 7000, you cannot use the SNMP commands SET and GET.
Community strings set permissions for the following:
Read Only Using the community string defined to have read permissions only, enables the person using the SNMP manager to read a MIB table using the GET command but does not allow the alteration of the MIB table using the SET command.
Write Only Using the community string defined to have write permissions only, this enables the person using the SNMP manager to write to a MIB table using the SET command but does not allow the alteration of the MIB table using the GET command.
Read and Write Allows the use of both the SET and GET commands included in SNMP.
To set the community strings:
1 . Select one of the six different communities that can be defined pressing the [RETURN] until the cursor appears in the required field.
2 . Use the space bar to toggle the access options.
3 . Use [TAB] to move the cursor to the community field.
4 . Type in the new community string. Press [RETURN] again for the change is to take effect.
By default any SNMP manager can access the Management Controller and configure and manage the unit. You can configure up to six SNMP managers authorized to manage the unit.
Index Lists up to six SNMP managers.
Type Set to Valid to authorize the SNMP manager or to Invalid to prevent access by the selected SNMP Manager.
Client IP Address Enter the IP address of the authorized SNMP Manager.